Kussmaul-electronics 091-167-12 User Manual

Browse online or download User Manual for For the car Kussmaul-electronics 091-167-12. Kussmaul Electronics 091-167-12 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
KUSSMAUL ELECTRONICS COMPANY, INC.
170 CHERRY AVENUE, WEST SAYVILLE, NEW YORK, 11796-1221 USA
SINCE 1967, DESIGNERS OF INNOVATIVE PRODUCTS
TEL. In NY: TOLL FREE: FAX:
631 567-0314 800 346-0857 631 567-582
6
INSTALLATION INSTRUCTIONS
Model 091-167-12 Load Manager 1HP
The 091-167-12, Load Manager 1HP is a small waterproof assembly that monitors a D.C. volt-
age and operates a relay when the voltage drops below its set point.
With the engine running and battery voltage above 12.8 volts, the relay is energized and power is
supplied to the loads.
With the engine stopped and continuous loads that reduce the battery below +11.5 volts, the
relay will drop out and prevent complete discharge of the battery. The relay remains de-ener-
gized until the battery voltage returns to +12.8 volts or higher.
An optional starter input prevents the relay from dropping out during the cranking cycle if the
voltage prior to cranking was sufficient (+11.5 volts).
Note: the starter input is not required for normal operation if cranking shutdown protection is not
required.
May 24, 2007
4
321
Radio &
Computer
Loads
From
+12V
Battery
Size Fuse
for 25% Higher
Than Actual
Load
Fuse
+12V
From
Starter
(optional)
75 Amp
Relay
Input:
Relay Contact Rating:
12.8 +/- 0.1 Volts
11.5 +/- 0.1 Volts
75 Amperes D.C.
Specifications:
+12 Volts Nominal
Relay Pull-In:
Relay Drop-Out:
Page view 0